Integrity Fiberglass Ultrex Glider Window
Wood-Ultrex

Round Top Windows

Integrity Wood-Ultrex Round Tops are available in a full line of quarter rounds, half rounds and elliptical to provide dramatic accents to your project. An integral nail provide exceptional stability and makes each unit extremely weather-tight. The strong, durable exterior and rich pine interior complements all of our Wood-Ultrex Series products.

  • Low-maintenance Ultrex exterior; rich pine interior
  • DP40 performance
  • Quarter rounds, half rounds and elliptical designs
  • Folding nail fin and all installation accessories included
  • 10-year manufacturing warranty/20-year glass seal warranty
  • LoE2 glass with argon gas standard
  • LoE3-366 and tempered glass available
Energy Data

Integrity Wood-Ultrex Round Top

ENERGY DATAU-FactorSHGCVTENERGY STAR
Insulating Glass/LoĒ-180 - Air - SDLN0.330.540.62
Insulating Glass/LoĒ-180 - Air0.330.590.69
Insulating Glass/LoĒ-180 - Air - GBG0.330.540.62
Insulating Glass/LoĒ-180 - Air - SDLS0.330.540.62
Insulating Glass/LoĒ-180 - Argon0.290.600.69N
Insulating Glass/LoĒ-180 - Argon - GBG0.290.540.62N
Insulating Glass/LoĒ-180 - Argon - SDLS0.290.540.62N
Insulating Glass/LoĒ-180 - Argon - SDLN0.290.540.62N
Insulating Glass/LoĒ²-272 - Air - GBG0.320.330.56NC
Insulating Glass/LoĒ²-272 - Air - SDLS0.320.330.56NC
Insulating Glass/LoĒ²-272 - Air - SDLN0.320.330.56NC
Insulating Glass/LoĒ²-272 - Air0.320.360.62NC
Insulating Glass/LoĒ²-272 - Argon - SDLS0.280.330.56N, NC
Insulating Glass/LoĒ²-272 - Argon - SDLN0.280.330.56N, NC
Insulating Glass/LoĒ²-272 - Argon0.280.360.62N, NC
Insulating Glass/LoĒ²-272 - Argon - GBG0.280.330.56N, NC
Insulating Glass/LoĒ³-366 - Air0.310.240.56NC, SC, S
Insulating Glass/LoĒ³-366 - Air - GBG0.310.220.50NC, SC, S
Insulating Glass/LoĒ³-366 - Air - SDLS0.310.220.50NC, SC, S
Insulating Glass/LoĒ³-366 - Air - SDLN0.310.220.50NC, SC, S
Insulating Glass/LoĒ³-366 - Argon - GBG0.270.220.50N, NC, SC, S
Insulating Glass/LoĒ³-366 - Argon - SDLS0.270.220.50N, NC, SC, S
Insulating Glass/LoĒ³-366 - Argon0.270.240.56N, NC, SC, S
Insulating Glass/LoĒ³-366 - Argon - SDLN0.270.220.50N, NC, SC, S

Integrity Casement Round Top By Marvin

ENERGY DATAU-FactorSHGCVTENERGY STAR
Insulating Glass/LoĒ-180 - Air0.340.610.71
Insulating Glass/LoĒ-180 - Air - GBG0.340.560.64
Insulating Glass/LoĒ-180 - Air - SDLS0.340.560.64
Insulating Glass/LoĒ-180 - Air - SDLN0.340.560.64
Insulating Glass/LoĒ-180 - Argon - SDLS0.300.560.64N
Insulating Glass/LoĒ-180 - Argon - SDLN0.300.560.64N
Insulating Glass/LoĒ-180 - Argon0.300.620.71N
Insulating Glass/LoĒ-180 - Argon - GBG0.300.560.64N
Insulating Glass/LoĒ²-272 - Air0.330.380.65
Insulating Glass/LoĒ²-272 - Air - GBG0.330.340.58
Insulating Glass/LoĒ²-272 - Air - SDLS0.330.340.58
Insulating Glass/LoĒ²-272 - Air - SDLN0.330.340.58
Insulating Glass/LoĒ²-272 - Argon - SDLN0.300.340.58N, NC
Insulating Glass/LoĒ²-272 - Argon0.300.370.65N, NC
Insulating Glass/LoĒ²-272 - Argon - GBG0.300.340.58N, NC
Insulating Glass/LoĒ²-272 - Argon - SDLS0.300.340.58N, NC
Insulating Glass/LoĒ³-366 - Air - SDLS0.330.230.52SC, S
Insulating Glass/LoĒ³-366 - Air - SDLN0.330.230.52SC, S
Insulating Glass/LoĒ³-366 - Air0.330.250.58SC, S
Insulating Glass/LoĒ³-366 - Air - GBG0.330.230.52SC, S
Insulating Glass/LoĒ³-366 - Argon0.290.250.58N, NC, SC, S
Insulating Glass/LoĒ³-366 - Argon - GBG0.290.220.52N, NC, SC, S
Insulating Glass/LoĒ³-366 - Argon - SDLS0.290.220.52N, NC, SC, S
Insulating Glass/LoĒ³-366 - Argon - SDLN0.290.220.52N, NC, SC, S

Integrity Double Hung Round Top By Marvin

ENERGY DATAU-FactorSHGCVTENERGY STAR
Insulating Glass/LoĒ-180 - Air0.340.590.68
Insulating Glass/LoĒ-180 - Air - GBG0.340.530.61
Insulating Glass/LoĒ-180 - Air - SDLS0.340.530.61
Insulating Glass/LoĒ-180 - Air - SDLN0.340.530.61
Insulating Glass/LoĒ-180 - Argon0.300.590.68N
Insulating Glass/LoĒ-180 - Argon - GBG0.300.530.61N
Insulating Glass/LoĒ-180 - Argon - SDLS0.300.530.61N
Insulating Glass/LoĒ-180 - Argon - SDLN0.300.530.61N
Insulating Glass/LoĒ²-272 - Air0.330.360.61
Insulating Glass/LoĒ²-272 - Air - GBG0.330.320.55
Insulating Glass/LoĒ²-272 - Air - SDLS0.330.320.55
Insulating Glass/LoĒ²-272 - Air - SDLN0.330.320.55
Insulating Glass/LoĒ²-272 - Argon0.290.360.61N, NC
Insulating Glass/LoĒ²-272 - Argon - GBG0.290.320.55N, NC
Insulating Glass/LoĒ²-272 - Argon - SDLS0.290.320.55N, NC
Insulating Glass/LoĒ²-272 - Argon - SDLN0.290.320.55N, NC
Insulating Glass/LoĒ³-366 - Air - SDLN0.320.220.50NC, SC, S
Insulating Glass/LoĒ³-366 - Air0.320.240.55NC, SC, S
Insulating Glass/LoĒ³-366 - Air - GBG0.320.220.50NC, SC, S
Insulating Glass/LoĒ³-366 - Air - SDLS0.320.220.50NC, SC, S
Insulating Glass/LoĒ³-366 - Argon0.290.240.55N, NC, SC, S
Insulating Glass/LoĒ³-366 - Argon - GBG0.290.210.50N, NC, SC, S
Insulating Glass/LoĒ³-366 - Argon - SDLS0.290.210.50N, NC, SC, S
Insulating Glass/LoĒ³-366 - Argon - SDLN0.290.210.50N, NC, SC, S
Architectural Detail Manuals (ADM)

Click a link below to download detailed product information, including sizes, features, design pressures, NFRC values, egress information, elevations and section details. Documents can be opened using Adobe Acrobat or compatible .pdf viewer.
Construction Specifications

Click a link below to download customizable specification information for use in preparing project documentation and submittals. Documents can be opened using Microsoft Word or compatible .doc viewer / editor.
Installation Instructions

Parts Manuals

Click a link below to view parts by product type. Documents provide part identification, as well as available and obsolete parts information. Documents can be opened using Adobe Acrobat or compatible .pdf viewer.
Sizes and Specs

Drawings and 3D Models

Symbols of standard window and door products are ready to insert directly into your ADT, SoftPlan, Chief Architect, ArchiCAD, VectorWorks, Home Designer, Revit and SketchUp Version 6 and now SketchUp Dynamic Components (Version 7 & 8) plans. Self-installing files are available.
2D
Drawings of standard window and door products are ready to insert directly into your architectural plans. To download, select a product type, wood or clad exterior surface and the drawing format you want.
Drawing Type
Operation Type
Performance Level
Surface
DWG File Type
Impact Zone 3 Round Top ElevationRound TopIZ3 Wood-Ultrex
ADT
Drawing Type
Operation Type
Performance Level
Surface
ZIP File Type